Hearing loss from loud blasts may be treatable
Using a mouse model, the study found that loud blasts actually cause hair-cell and nerve-cell damage, rather than structural damage, to the cochlea, which is the auditory portion of the inner ear. This could be good news for the millions of soldiers and civilians who, after surviving these often devastating bombs, suffer long-term hearing damage.
"It means we could potentially try to reduce this damage," said John Oghalai, MD, associate professor of otolaryngology and senior author of the study, published July 1 in PLOS ONE. If the cochlea, an extremely delicate structure, had been shredded and ripped apart by a large blast, as earlier studies have asserted, the damage would be irreversible. (Researchers presume that the damage seen in these previous studies may have been due to the use of older, less sophisticated imaging techniques.)
"The most common issue we see veterans for is hearing loss," said Oghalai, a scientist and clinician who treats patients at Stanford Hospital & Clinics and directs the hearing center at Lucile Packard Children's Hospital.
The increasingly common use of improvised explosive devices, or IEDs, around the world provided the impetus for the new study, which was primarily funded by the U.S. Department of Defense. Among veterans with service-connected disabilities, tinnitus -- a constant ringing in the ears -- is the most prevalent condition. Hearing loss is the second-most-prevalent condition. But the results of the study would prove true for anyone who is exposed to loud blasts from other sources, such as jet engines, air bags or gunfire.
More than 60 percent of wounded-in-action service members have eardrum injuries, tinnitus or hearing loss, or some combination of these, the study says. Twenty-eight percent of all military personnel experience some degree of hearing loss post-deployment. The most devastating effect of blast injury to the ear is permanent hearing loss due to trauma to the cochlea. But exactly how this damage is caused has not been well understood.
The ears are extremely fragile instruments. Sound waves enter the ear, causing the eardrums to vibrate. These vibrations get sent to the cochlea in the inner ear, where fluid carries them to rows of hair cells, which in turn stimulate auditory nerve fibers. These impulses are then sent to the brain via the auditory nerve, where they get interpreted as sounds.
Permanent hearing loss from loud noise begins at about 85 decibels, typical of a hair dryer or a food blender. IEDs have noise levels approaching 170 decibels.
Damage to the eardrum is known to be common after large blasts, but this is easily detected during a clinical exam and usually can heal itself -- or is surgically repairable -- and is thus not typically the cause of long-term hearing loss.
In order to determine exactly what is causing the permanent hearing loss, Stanford researchers created a mouse model to study the effects of noise blasts on the ear.
After exposing anesthetized mice to loud blasts, researchers examined the inner workings of the mouse ear from the eardrum to the cochlea. The ears were examined from day one through three months. A micro-CT scanner was used to image the workings of the ear after dissection.
"When we looked inside the cochlea, we saw the hair-cell loss and auditory-nerve-cell loss," Oghalai said.
"With one loud blast, you lose a huge number of these cells. What's nice is that the hair cells and nerve cells are not immediately gone. The theory now is that if the ear could be treated with certain medications right after the blast, that might limit the damage."
Previous studies on larger animals had found that the cochlea was torn apart and shredded after exposure to a loud blast. Stanford scientists did not find this in the mouse model and speculate that the use of older research techniques may have caused the damage.
"We found that the blast trauma is similar to what we see from more lower noise exposure over time," said Oghalai. "We lose the sensory hair cells that convert sound vibrations into electrical signals, and also the auditory nerve cells."
Much of the resulting hearing loss after such blast damage to the ear is actually caused by the body's immune response to the injured cells, Oghalai said. The creation of scar tissue to help heal the injury is a particular problem in the ear because the organ needs to vibrate to allow the hearing mechanism to work. Scar tissue damages that ability.
"There is going to be a window where we could stop whatever the body's inflammatory response would be right after the blast," Oghalai said. "We might be able to stop the damage. This will determine future research."
In addition to the Department of Defense, the study was funded by the National Institutes of Health (grants K08DC006671 and P30DC010363) and Chosun University in South Korea.
The first author of the study, Sung-Il Cho, MD, assistant professor at Chosun University, was working at Stanford during the study. Other Stanford authors were graduate students Simon Gao, Jongmin Baek and David Jacobs; senior research scientist Anping Xia, MD, PhD; research technician Rosalie Wang; research associate Felipe Salles, PhD; computer programmer Patrick Raphael; and research coordinator Homer Abaya.
Welcome to SUV System Ltd!
SUV System Ltd is ISO 90012008 Certified electronics distributor with 10 years of experiences.
We have built up long term business relationship with about many companies which are stockers and authorized agents. we have a steady and reliable supply to meet customer's demands to the greatest extent .Confidently, we are able to lower your cost and support your business with our years of professional service.
SUV System Ltd is Electronic Components Distributor Supplies,Find Quality Electronic Components Supplies Products IC(Integrated Circuits),Connectors,Capacitor,Resistors,Diodes,Transistors,LED at Suvsystem.com. Sourcing Other Energy, Environment, Excess Inventory Products from Manufacturers and Suppliers at Suvsystem.com
Electronic Components distributor:http://www.suvsystem.com
Connectors Distributor:http://www.suvsystem.com/l/Connectors-1.html
IC Distributor:http://www.suvsystem.com/l/IC(Integrated-Circuits)-1.html
LED Distributor:http://www.suvsystem.com/l/LED-1.html
Capacitor Distributor:http://www.suvsystem.com/l/Capacitor-1.html
Transistor Distributor:http://www.suvsystem.com/l/Transistors-1.html
Resistor Distributor:http://www.suvsystem.com/l/Resistors-1.html
Diode Distributor:http://www.suvsystem.com/l/Diodes-1.html
SUV System Ltd insists on the managing faith ofsincereness,speciality,foresight, win-win,so we build up stable-relationship customers located all over the world, including the States, Europe, Argentina, UAE, Malaysia, Australia,and India etc
we are focus on the following fields,and hope we can help you.
52746-1190 52746-1170 52746-1090 52746-1070 52746-0970 52746-0890 52746-0870 52746-0790 52746-0770 5282-8SG-3DC 5282-8PG-3DC 5282-7SG-3DC 5282-7PG-3DC 5282-6SG-3DC 5282-6PG-3DC 5282-5SG-3DC 5282-5PG-3DC 5282-4SG-3DC 5282-4PG-3DC 52808-2690 52806-3010 52806-0810 52806-0570 52806-0510 5280 527R-01LF 52793-0990 52792 52791 5279 52772-1 52760-1409 52755-1760 52755-1209 52752 5275-1-05-15-00-00-01-0 5275-1-05-01-00-00-01-0 52751 52750 52749
http://www.suvsystem.com/a/3410.aspx
No comments:
Post a Comment